Lightolier
Calculite Evolution
C3ALV

Item Number: C3ALV

Lightolier<br>Calculite Evolution<br>C3ALV

 
Our Price: $129.95
 

Calculite Evolution Non-IC Airseal Frame-In Kit C3ALV 3” Aperture, MR16 (12V)

Ceiling Cutout: 3-1/2” (89 mm) Dia.

Specs
  • Magnetic Transformer
  • Input Voltage: 120V/277V
  • Lamp: 42W-65W MR16 (12V)
  • Length: 14 3/8"
  • Width: 9 9/16"
  • Height: 5"
Features
  1. Housing: Drawn, 0.036" (20 Ga.) steel. Matte black finish. Tight rigidly built
    housing minimizes air leakage to less than 2 CFM at 1.57 PSF (or 75pa),
    which complies with Model Energy Code and Washington State Energy Code
    and reduces heat loss and condensation in ceiling.
  2. Mounting Frame: Die-formed, 0.036" (20 Ga.) steel, matte black finish. 1/2"
    deep integral lip. Four slots are positioned 90° apart to simplify alignment.
  3. Trim Kit Horizontal Adjustment Mechanism: Die-formed steel ring, matte
    black finish. Provides 362°horizontal stop, lockable with Philips screwdriver.
  4. Thick Ceiling Vertical Adjustment Mechanism: Adjustable trim kit vertically
    to accommodate up to 2" thick ceiling, tool less and lockable.
  5. Mounting Bars: Galvanized steel, 0.059" (#16 ga.). Bars pivot for easy
    attachment and wire-in below ceiling line. Pre-installed telescoping bars
    extend to accommodate 16" to 24" O.C. joist spacing. Bars can accommodate
    12" O.C. joist spacing after a slight field modification. Integral nails for
    secure attachment to wood; attach to T-bar ceilings with out the need of accessories.
  6. Lamp holder: Procelain bi-pin socket. Pre-wired with No.18 AWG Teflon leads.
  7. Junction Box: 3-1/2" X 4" X 2-3/8" deep; 0.063" (#14 ga.) galvanized steel.
    UL listed for maximum of (8) No. 12 AWG 90°C through branch circuit conductors.
    Accessible from inside and outside of luminaire. Outside J-Box door
    is hinged for maximum opening.
  8. Thermal Protector (not shown): Meets NEC and UL requirements. Insulation must be
    kept 3" away from any parts of the luminaire and must not be placed above
    luminaire in a manner which will entrap heat.
  9. Trim Kit: Order Separately. See individual trim kit specification sheets for information.
Electrical:

Transformer: Replaceable from below; Transformer door rotates into fixture, positioning
transformer directly over aperture to allow one-handed removal Magnetic:
120V/277V 60 Hz. dual-voltage, core & coil. Electronic: 120V or 277V 50/60 Hz.,
regulated lamp voltage, HPF, EMI and circuit protections, thermal auto-reset, quiet operation.

Dimming Controls: Use only dimmers specifically designed for use with
magnetic or electronic transformers. Consult Lightolier Control for information.
Low voltage luminaires may produce audible sound when used with dimmers,
which may be objectionable in acoustically critical areas.

Labels

U.L. (Suitable For Damp Locations), I.B.E.W. U.S. & Foreign Patents pending.
Complies with Air Leakage Requirements as stated in the Model Energy Code
and the Washington State Energy Code.