Calculite Evolution Non-IC Frame-In Kit C3LV 3” Aperture, MR16 (12V)
Ceiling Cutout: 3-1/2” (89 mm) Dia.
Specs
- Magnetic Transformer
- Input Voltage: 120V/277V
- Lamp: 42W-65W MR16 (12V)
- Length: 14 3/8"
- Width: 12 11/16"
- Height: 5"
Features
- Housing: Drawn, 0.036" (20 Ga.) steel. Matte black finish.
- Mounting Frame: Die-formed, 0.036" (20 Ga.) steel, matte black finish. 1/2"
deep integral lip. Four slots are positioned 90° apart to simplify alignment.
- Trim Kit Horizontal Adjustment Mechanism: Die-formed steel ring, matte
black finish. Provides 362°horizontal stop, lockable with Philips screwdriver.
- Thick Ceiling Vertical Adjustment Mechanism: Adjustable trim kit vertically
to accommodate up to 2" thick ceiling, tool less and lockable.
- Frame Vertical Adjustment Mechanism: Accommodates mounting to
virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking features secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. Final adjustment can be made from belowinside fixtures.
- Mounting Bars: Galvanized steel, 0.048”; pre-installed telescoping
bars extend from 20” to 30” long and lock securely into position. Built-in locking ingtabs provide positive attachment to common T-bar systems. Self-centering feature simplified installation in 24”O.C. grid systems. Attaches to steel or wood joists without accessories.
- Lamp holder: Procelain bi-pin socket. Pre-wired with No.18 AWG Teflon leads.
- Junction Box: 3-1/2" X 4" X 2-3/8" deep; 0.063" (#14 ga.) galvanized steel.
UL listed for maximum of (8) No. 12 AWG 90°C through branch circuit conductors. Accessible from inside and outside of luminaire. Outside J-Box door is hinged for maximum opening.
- Thermal Protector (not shown): Meets NEC and UL requirements. Insulation must be
kept 3" away from any parts of the luminaire and must not be placed above luminaire in a manner which will entrap heat.
- Trim Kit: Order Separately. See individual trim kit specification sheets for information.
Electrical:
Transformer: Replaceable from below; Transformer door rotates into fixture, positioning transformer directly over aperture to allow one-handed removal Magnetic: 120V/277V 60 Hz. dual-voltage, core & coil. Electronic: 120V or 277V 50/60 Hz., regulated lamp voltage, HPF, EMI and circuit protections, thermal auto-reset, quiet operation.
Dimming Controls: Use only dimmers specifically designed for use with magnetic or electronic transformers. Consult Lightolier Control for information. Low voltage luminaires may produce audible sound when used with dimmers, which may be objectionable in acoustically critical areas. Labels
U.L. (Suitable For Damp Locations), I.B.E.W. U.S. & Foreign Patents pending.
|