Lightolier Lytecaster Recessed Downlighting 1100AICMFT
6 3/4”Aperture Fluorescent 1 Lt. 26/32W Triple Tube Insulated Ceiling, AirSeal Frame-In Kit
Height: 6 13/16"
Width: 9"
| Reflector Trims | |
| Open Downlight Trims: 1112, 1113, 1105, 1105WH, 1176, 1176WH. |
Wattage & Lamp Type:
26W - 32W
PL-T by Philips
DULUX by Osram Sylvania
Triple BIAX by GE
|
Enclosed Diffusers (shower): 1121, 1124, 1177SH, 1178SH.
Wall Washers: 1185, 1186, 1186WH. |
Wattage & Lamp Type:
26W
PL-T by Philips
DULUX by Osram Sylvania
Triple BIAX by GE
|
Features
- Housing: .026” galvanized steel. ULlisted for direct contact with thermal
insulation. AirSeal ®housing minimizes air leakage to less than 2 CFM at 1.57 PSF, which complies with Model Energy Code (Section 602.3.3) and the Washington State Energy Code (Section 502.4) and reduces heat loss and condensation in ceiling. Access door for inspection of junction box.
- Mounting Frame: .036 (#20 ga.) galvanized steel. Accommodates all ceilings
up to 1”thick. 3/8” deep integral lip. Four slots are positioned 90° apart to simplify alignment. Push-in/twist-out rotoclips hold reflector flush to ceiling.
- Junction Box: 2” X 4” X 4”: .063” (#14 ga.) galvanized steel. ULlisted for
maximum of 6 No. 12 ga., 90°C through branch circuit conductors. Quick release “L”shaped cover for outside access to wiring. Access door inside of housing allows easy inspection of wiring without removal of housing. Integral cable clamps permit attachment of nonmetallic Romex or armored without the need for additional connectors.
- Mounting Bars: .059” (#16 ga.) galvanized steel. Bars pivot for easy
attachment and wire-in below ceiling line. Bars extend to accommodate 16” to 24” O. C. joist spacing and feature integral nail for secure attachment to wood construction. Attaches to T-bar ceilings without the need of accessories.
- Ballast: Electronic, encased and potted, thermally protected, Class “P”,
Normal Power Factor, 120V.
- Socket:4-pin Gx24q-3 base compact fluorescent. Pre-wired with #18 ga.
TFN leads to junction box.
Labels
UL Type I.C. (Suitable for Damp Locations);
Complies with Air Leakage Requirements as stated in the Model Energy Code and the Washington State Energy Code.
|